We Buy 38kV Switchgear from 34.5kV Campuses
Data Center Buyers buys used and surplus 38 kV switchgear from customer-owned substations, 34.5 kV campus distribution, and collector systems throughout the US and Canada. Submit complete lineups, individual feeder sections, or pad-mounted units with nameplate photos and an asset list. We provide a written offer within 24 hours after receiving that information. Call 951-403-5738 or request a quote online.

Selling 38kV Switchgear: What to Know
A 34.5 kV system voltage and a 38 kV equipment rating describe different things. Manufacturer catalogs identify 38 kV class switchgear for this distribution level; the equipment's maximum voltage rating is not the campus's normal operating voltage. Sellers should record both rather than advertising everything as simply 35 kV gear. At a hyperscale data center, a crypto-mining campus, or a large industrial site using 34.5 kV distribution, identify the customer-owned incoming and outgoing feeders available for purchase. A one-line diagram helps separate the assets being sold from utility-owned equipment and circuits that must remain in operation.
For a complete 38 kV lineup, the offer depends on more than cabinet count. Siemens GM38 and Eaton VacClad-W 38 kV are documented metal-clad families, while S&C Vista and G&W Electric offer pad-mounted equipment with ratings through 38 kV. These are different assemblies, not interchangeable packages. Preserve the relationship between each feeder, its switching or interrupting device, and its controls. Include sections held for a canceled expansion as well as equipment released by a shutdown. Data Center Buyers purchases single breakers through full power rooms and campuses; a partial removal can be considered when the asset boundaries and remaining installation are clearly described.
38kV Switchgear We Buy
38 kV metal-clad feeder lineups
- Siemens GM38 sections with their matched vacuum breakers, control compartments, and original section identification.
- Eaton VacClad-W 38 kV lineups with available drawings identifying the installed main and feeder configuration.
- Customer-owned 34.5 kV substation incoming, tie, and outgoing feeder sections offered together or as defined lots.
- Installed or never-installed 38 kV expansion sections with readable assembly ratings and documented storage history.
35/38 kV pad-mounted distribution equipment
- 38 kV S&C Vista pad-mounted units with an inventory of load-interrupter and fault-interrupter ways.
- G&W Electric pad-mounted gas-insulated assemblies rated through 38 kV, identified by their exact nameplates.
- Campus loop switching units serving a documented 34.5 kV system, with controls and enclosure panels included.
- Equipment described on site as 35 kV gear, submitted with actual maximum voltage and insulation ratings.
34.5 kV campus and collector feeder lots
- Customer-owned feeder assemblies released when a hyperscale campus changes its substation or distribution arrangement.
- Identifiable 38 kV switchgear from a crypto-mining site's closure, relocation, or revised power delivery plan.
- Collector-system switchgear with circuit drawings showing which incoming and outgoing feeder sections are included.
- Large industrial campus lots with matching metering sections, control cabinets, and accessories retained with the gear.
What Affects Your Offer for 38kV switchgear
Actual voltage and insulation ratings
Send the rated maximum voltage and basic impulse level, or BIL, from the assembly and device plates. Siemens GM38 documentation lists 38 kV maximum voltage and 150 kV BIL. A site description of 34.5 kV alone does not establish every component's rating.
Continuous current and fault duty
Siemens GM38 documentation includes 1,200 A and 2,000 A breakers with 31.5 kA or 40 kA symmetrical short-circuit ratings. These are examples, not assumed ratings for your lineup. Photograph both breaker and assembly plates, and keep continuous, interrupting, and momentary values separately identified.
Feeder configuration and matching components
The number of usable feeders, installed breakers, spare cells, and retained controls changes how the lot can be evaluated. For pad-mounted units, count load-interrupter and fault-interrupter ways separately. Missing devices or unidentified modifications can limit the fit for another installation.
Condition and operating records
Disclose the last operating date, known trips, moisture exposure, corrosion, damaged insulation, and missing parts. Existing maintenance records and factory reports help explain the equipment's history. An unused section stored poorly needs a different assessment from one with documented protected storage.
Ownership and removal boundaries
Identify which 34.5 kV substation assets belong to your company and which remain with the utility or landlord. Provide the proposed separation points on drawings, the shutdown window, and physical access constraints. Clear boundaries help avoid quoting sections that cannot actually leave the site.
For broader pricing context, read our guide: Used switchgear value on the secondary market.
What to Send for an Accurate Quote
- An asset list identifying manufacturer, family, serial numbers, section quantities, installed devices, and whether each asset is customer-owned or excluded from the sale.
- Clear assembly and breaker nameplate photos showing maximum voltage, continuous amperes, short-circuit ratings, BIL, frequency, and any cooling-dependent rating information already recorded.
- A one-line diagram marking the 34.5 kV feeders included, their normal system voltage, and neighboring circuits that must stay operational during the project.
- Exterior photos of the complete lineup or pad-mounted enclosure, plus safely available photos of section labels, controls, accessories, and visible damage. Do not open energized compartments for photographs.
- Available outline drawings, section weights, original factory reports, maintenance history, and a list of missing breakers, controls, covers, or inter-section connection hardware.
- For pad-mounted units, the way configuration, insulation medium, readable equipment ratings, and existing records of gas-pressure issues or leaks where applicable.
- Site city and country, removal deadline, outage availability, gate and loading access, crane restrictions, and any security or operating requirements affecting pickup.
When Companies Sell 38kV switchgear
- A hyperscale campus replaces a customer-owned 34.5 kV feeder lineup after the new distribution path is commissioned, releasing identified 38 kV sections for purchase.
- A crypto-mining operator closes one campus and offers its customer-owned 38 kV pad-mounted distribution units without including utility equipment or assets retained at the property.
- A large industrial campus consolidates its electrical supply, leaving 38 kV feeder sections and their associated controls surplus to the revised one-line diagram.
- A canceled campus or collector-system expansion leaves never-installed 38 kV switchgear available, with project drawings and storage records describing exactly what was delivered.
Removal, Safety, and Logistics
Qualified electricians must de-energize and lock out the gear before disconnection; all disconnection must be complete before removal work begins. We coordinate removal with your electrician or facility team around adjacent live circuits and uptime needs. Share section weights, lifting provisions, and the route out of the substation before dismantling. When we purchase, de-installation, rigging, and insured freight nationwide are included, with no removal or recycling fees deducted from the offer. Pickup is typically scheduled within a few business days after acceptance. Keep feeder labels and matching hardware together, and agree on any gas-handling responsibilities before moving gas-insulated units.
Power Equipment Removal Is Planned Before Pickup
This owner-provided project photo shows data center power equipment secured on a flatbed during a removal. Switchgear sections, breakers, and transfer equipment are heavy, so dimensions, weights, access routes, and rigging needs are confirmed with your team before the truck arrives.

Get a Written Offer for Your 38kV Switchgear
Send nameplate photos, quantities, and your removal timeline. We reply with a written offer within 24 hours of receiving the list and photos.
38kV Switchgear: Seller Questions
Should I list my 34.5 kV feeder lineup as 35 kV or 38 kV when requesting an offer?
Use the equipment nameplate designation and list the normal system voltage separately. Manufacturer documentation supports 38 kV class equipment for 34.5 kV applications. If your records call it 35 kV, include that description without changing the plate rating. Send BIL and device ratings too; the informal voltage label does not prove compatibility or identify the actual assembly.
What documentation matters for a Siemens GM38 removed from a customer-owned substation?
Send assembly plates, breaker plates, the section arrangement, and the original one-line if available. Siemens identifies GM38 as metal-clad equipment under ANSI/IEEE C37.20.2. Record the installed ratings rather than inferring them from that standard or family name. Describe relays, control power, and modifications, and mark utility-owned metering or other excluded assets so the offered lot is clear.
Can a 38 kV pad-mounted unit from a 34.5 kV loop be quoted with loadbreak ways only?
Yes, submit its exact configuration for consideration. A load-interrupter way is not the same asset as a fault-interrupter way, so identify each separately rather than counting every way as a circuit breaker. Include the nameplate, controls, and connection arrangement shown on existing drawings. For gas-insulated equipment, disclose the insulation medium and known pressure or leakage issues without opening the sealed equipment.
Can I offer only the outgoing 38 kV feeders while keeping the 34.5 kV incoming service?
A partial lot can be considered, but show the proposed asset boundary on the one-line and section drawings. Identify shared bus, controls, and hardware that must remain with the incoming service. Your qualified electrical team must determine the safe separation plan. Do not dismantle first to make the lot appear independent; describe what can leave and the permitted outage window before accepting removal arrangements.
How are older 38 kV collector-system sections evaluated and paid for?
Older or non-working sections can still have resale or parts value when their identity and condition are clear. Send the feeder inventory, known faults, and missing-component list for a written offer within 24 hours after we receive the asset list and photos. Payment is by company check or wire transfer, on pickup or per agreed terms for larger projects. Material that cannot be resold is recycled responsibly.
Related Switchgear We Buy
- Medium-Voltage Switchgear
- Metal-Clad Switchgear
- Pad-Mounted Switchgear
- Service-Entrance Switchgear
- All Electrical Switchgear
38kV Switchgear Brands We Buy
Get a written offer within 24 hours
Send your asset list and we respond with a firm written offer, typically within one business day. We pay top dollar, handle rigging and freight, and provide secure data wiping with a certificate on request.
Call 951-403-5738 or request a quote online.