Data Center Buyers buys used and surplus 27kV switchgear from data centers and industrial campuses throughout the US and Canada. Send the assembly nameplate, actual system voltage, section list, and photos before dismantling the gear. We provide a written offer within 24 hours after receiving the asset list and photos. Call 951-403-5738 or request a quote online to discuss your shutdown window.

Selling 27kV Switchgear: What to Know
A 27 kV equipment rating is not the same as a site's operating voltage. This class can serve 22.86 kV and 24.94 kV distribution systems when the complete assembly is appropriate for the application. Eaton's distribution guidance lists those systems as 22.86Y/13.2 kV and 24.94Y/14.4 kV, separating line-to-line from line-to-neutral voltage. In North America, sellers may encounter this gear at customer-owned primary distribution points and campus feeders supplied by local 25 kV-class networks, including service areas in the Upper Midwest. At a data center, identify which transformer feeders and power trains the offered sections served rather than describing them only as a utility entrance.
The buyer pool for a particular 27 kV lineup is narrower than a general medium-voltage equipment listing suggests. Another facility needs a suitable voltage rating, protection arrangement, physical layout, and interface with its existing distribution. That makes precise identification more useful than a long list of possible applications. Metal-clad vacuum-breaker lineups, metal-enclosed load-interrupter assemblies, and pad-mounted switch-and-fuse gear exist at this rating, but they are not interchangeable packages. Keep the manufacturer's assembly label with the section schedule. If a campus upgrade releases only part of a lineup, identify its original position and the neighboring sections that will remain in service before submitting the equipment for an offer.
27kV Switchgear We Buy
27 kV metal-clad breaker lineups
- Eaton VacClad-W 27 kV assemblies with their matched drawout vacuum breakers, section identification, and available factory drawings.
- Main, tie, and feeder sections from 22.86 kV or 24.94 kV campus distribution, with actual system voltage documented separately.
- Nameplated 1200 A or 2000 A VacClad-W lineups; Eaton's current 27 kV design guide also lists 2500 A and 3000 A main buses.
- Indoor or outdoor aisleless 27 kV VacClad-W assemblies, offered with their associated auxiliary drawers and control cabinets.
27 kV metal-enclosed switch assemblies
- Eaton MVS 27 kV load-interrupter switchgear, identified by its assembly nameplate rather than the connected transformer's voltage alone.
- Fixed-switch sections with primary power fuses, including the fuse identification and available records of the original protective arrangement.
- 600 A Eaton MVS assemblies in stand-alone or multi-section configurations, with indoor or outdoor enclosure details recorded.
- Transformer-primary switch sections released from a 25 kV-class campus network, with bus connections and matching enclosure parts identified.
27 kV-rated pad-mounted distribution gear
- S&C PMH pad-mounted switch-and-fuse gear with documented 27 kV maximum ratings; its nominal 25 kV description alone is insufficient.
- Manual PMH configurations offered with the installed fuse types, circuit arrangement, and manufacturer identification clearly listed.
- Source-transfer or remote supervisory PMH assemblies, with the associated operators and controls identified as part of the offered package.
- Customer-owned outdoor distribution cabinets from campus loops, with enclosure condition, cable-interface details, and ownership boundaries disclosed.
What Affects Your Offer for 27kV switchgear
Assembly rating versus operating voltage
Record both the maximum equipment voltage and the former 22.86 kV or 24.94 kV system voltage. A nominal 25 kV description can hide important configuration differences. The assembly label and drawings help establish what is actually being offered.
Current and fault-duty identification
Supply main-bus amperage, each switching device's rating, and the documented fault-duty values. Eaton's 27 kV VacClad-W guide lists assembly short-circuit ratings of 16, 22, 25, and 40 kA rms symmetrical. Those options do not establish the rating of your particular lineup.
Construction and circuit arrangement
A breaker lineup, fixed load-interrupter assembly, and pad-mounted package reach different potential users. Section order, feeder count, tie arrangement, and available cable-entry space affect reuse. Keep the one-line diagram and physical layout together so a voltage match is not mistaken for a complete application match.
Complete matched equipment and records
Missing breakers, fuse hardware, instrument transformers, or section connections can limit interest in a less common voltage class. List what remains with the assembly and what the facility will retain. Documented modifications help distinguish original factory equipment from later additions.
Condition and removal constraints
Report moisture exposure, corrosion, insulation damage, unresolved faults, and the last operating date. For a large 27 kV lineup, shipping splits and access restrictions also matter. Older or non-working equipment may retain resale or parts value, but condition must be described honestly.
For broader pricing context, read our guide: Used switchgear value on the secondary market.
What to Send for an Accurate Quote
- Clear assembly nameplate photos showing manufacturer, serial number, rated maximum voltage, main-bus current, and listed short-circuit or withstand ratings.
- The former system voltage, including whether a drawing's 13.2 kV or 14.4 kV reference is line-to-neutral rather than line-to-line.
- A section-by-section asset list with breaker or switch identification, installed fuse types, auxiliary compartments, and quantities of matching equipment included.
- Available one-line diagrams, general arrangement drawings, shipping-split plans, and records explaining any changes to the original 27 kV configuration.
- Exterior photos of the complete lineup or cabinet, enclosure labels, visible damage, and accessible device labels; do not open energized compartments.
- Existing maintenance reports, last operating date, known faults, storage history, and a list of parts already removed or reserved for the facility.
- Site city and country, ownership confirmation, shutdown window, removal deadline, loading access, and nearby distribution sections that must remain operational.
When Companies Sell 27kV switchgear
- A data center changes its utility supply arrangement, leaving customer-owned 27 kV primary gear available after replacement feeders are commissioned.
- An industrial campus replaces a 24.94 kV feeder lineup, releasing matched sections and drawings while retaining other portions of its distribution network.
- A cancelled campus expansion leaves unused 27 kV switch assemblies whose configured voltage and circuit arrangement no longer match the revised project.
- A facility consolidation makes a 22.86 kV distribution branch unnecessary, allowing its owned switchgear to be offered around an agreed shutdown and removal plan.
Removal, Safety, and Logistics
The 27 kV gear must be de-energized and locked out by qualified electricians before disconnection. Removal is coordinated with your electrician or facility team, and disconnection happens before any removal work. Do not operate switches or withdraw breakers for quote photographs. Share assembly dimensions, documented weights, shipping splits, and access restrictions before rigging is planned. When we purchase, de-installation, rigging, and insured freight nationwide are included, with no removal or recycling fees deducted from the offer. Keep section labels, connection hardware, and drawings associated with the assembly. Pickup is typically scheduled within a few business days after acceptance, around access, security, and uptime needs.
Power Equipment Removal Is Planned Before Pickup
This owner-provided project photo shows data center power equipment secured on a flatbed during a removal. Switchgear sections, breakers, and transfer equipment are heavy, so dimensions, weights, access routes, and rigging needs are confirmed with your team before the truck arrives.

Get a Written Offer for Your 27kV Switchgear
Send nameplate photos, quantities, and your removal timeline. We reply with a written offer within 24 hours of receiving the list and photos.
27kV Switchgear: Seller Questions
Should I list my 24.94 kV campus lineup as 25 kV or 27 kV equipment?
Use the equipment nameplate rating and list 24.94 kV separately as the former system voltage. A site description such as 25 kV distribution is not a substitute for the assembly's maximum rating. Include the full drawing notation if available: 24.94Y/14.4 kV identifies line-to-line and line-to-neutral values. This avoids comparing equipment using different voltage references and gives a clearer starting point for evaluating the offered lineup.
Can a 22.86 kV feeder drawing establish the rating of an unmarked switchgear section?
It helps describe the former application, but it does not establish the section's rating by itself. Send the drawing with any remaining manufacturer labels, serial numbers, and section schedule. Identify missing nameplates explicitly. A complete assembly may include components with different limitations, so neither operating voltage nor an adjacent section's label should be treated as proof of the offered section's maximum voltage or fault duty.
Why does a 27 kV lineup need more than a voltage match to attract a buyer?
The potential user also needs appropriate current and fault ratings, compatible switching devices, and a layout that fits its distribution scheme. The narrower pool for this voltage class makes incomplete identification especially limiting. Explain whether the offered equipment is a complete lineup or selected sections, and preserve its one-line and arrangement drawings. A clear package helps distinguish realistic reuse possibilities from interest based only on a nominal voltage description.
Are all nominal 25 kV S&C PMH cabinets rated for a maximum of 27 kV?
No. S&C's PMH ratings table shows nominal 25 kV configurations with maximum ratings that depend on the fuse arrangement. The listed SML-20 and SML-4Z configurations have 27 kV maximum ratings, while the listed Fault Fiter configuration has a different maximum. Send the actual cabinet and fuse identification rather than assuming all PMH packages have identical ratings. Do not disturb energized gear to inspect a fuse label.
Can I submit an installed 27 kV main-tie-feeder lineup before the campus shutdown?
Yes. Send safely obtainable exterior photos, nameplate information, drawings, and the planned shutdown window while it remains installed. Identify any sections supporting other campus loads and confirm which assets you own. We provide a written offer within 24 hours after receiving the asset list and photos, typically one business day. Payment is by company check or wire transfer, on pickup or per agreed terms for larger projects. Isolation and removal planning remain separate from the quote.
Related Switchgear We Buy
- Medium-Voltage Switchgear
- Metal-Clad Switchgear
- Metal-Enclosed Switchgear
- Pad-Mounted Switchgear
- All Electrical Switchgear
27kV Switchgear Brands We Buy
Get a written offer within 24 hours
Send your asset list and we respond with a firm written offer, typically within one business day. We pay top dollar, handle rigging and freight, and provide secure data wiping with a certificate on request.
Call 951-403-5738 or request a quote online.