We Buy Used MCC Lineups, Starter Buckets and VFD Units
Data Center Buyers buys used and surplus motor control centers from data center mechanical plants and industrial facilities throughout the US and Canada. We evaluate complete MCC lineups, starter buckets and variable frequency drive units. Send the lineup nameplate, a bucket inventory and photos through our online quote form, or call 951-403-5738. When we purchase, de-installation, rigging and insured freight are included.

Selling Motor Control Centers: What to Know
An MCC sale starts with the motor-control units, not just the number of standing cabinets. UL 845 covers motor control centers, which group motor controls and associated equipment in a common assembly. In data center mechanical plants, these assets can serve chilled-water pumps, cooling-tower fans and air handlers, or support a chiller installation. A lineup containing starter buckets has a different equipment mix from one containing variable frequency drives, or VFDs. Identify each occupied position, the original equipment family and any units added later. Keep the current bucket schedule with the lineup so a buyer can distinguish installed controls from empty spaces reserved for expansion.
Cooling upgrades can leave useful MCC equipment behind even when the facility no longer needs its original configuration. Complete assemblies may suit another project, while identifiable buckets can have value as components for a retained platform. Neither a matching brand nor a similar door size establishes compatibility. We need catalog information, electrical ratings and photographs to evaluate the actual equipment. Data Center Buyers provides a written offer within 24 hours, typically one business day, after receiving the asset list and photos. Describe which cooling circuits must remain operational and when the surplus sections become available. You can submit installed equipment before arranging its safe shutdown and removal.
Motor Control Centers We Buy
Identifiable low-voltage MCC families
- Allen-Bradley CENTERLINE 2100 lineups and identifiable motor-control buckets, with section and unit labels retained.
- Square D Model 6 motor control centers, including starter and drive units documented on the bucket schedule.
- Eaton Freedom motor control centers, with the specific generation and installed unit mix recorded in the asset list.
- Siemens tiastar motor control centers, including complete sections and separately identified surplus motor-control units.
Starter buckets and motor-control units
- Full-voltage nonreversing starter buckets for motor loads, with contactor, overload relay and disconnect details identified.
- Reversing starter units, listed separately from nonreversing units rather than combined under one starter count.
- Eaton Freedom starter units labeled NEMA Size 1 through Size 5, with control voltage and catalog information.
- Soft-starter units held as spares or removed with an MCC, with controller labels and known condition disclosed.
VFD buckets from mechanical plants
- MCC-mounted VFD units from chilled-water or condenser-water pump circuits, with drive horsepower and output current recorded.
- Drive buckets serving cooling-tower fans or air handlers, with input voltage and exact drive identification supplied.
- Drive units with associated bypass equipment, where installed, listed with the bucket rather than assumed from the door controls.
- Unused spare VFD buckets and removed drive units, kept with their matching doors, keypads and available documentation.
Complete and partial MCC assemblies
- Complete UL 845 MCC lineups with their original nameplates, bucket schedules and available electrical drawings.
- 480 V or 600 V MCC equipment where those ratings appear on the labels; actual unit ratings remain essential.
- Partial MCC sections and loose spare buckets with documented origin, position numbers and any missing items disclosed.
- Older or non-working MCC units offered for evaluation, with damaged components distinguished from intact buckets.
What Affects Your Offer for motor control centers
Family, generation and bucket fit
The lineup family and individual bucket catalog numbers help establish potential reuse. Record unit height, mounting arrangement and original section position. A bucket with an unknown origin is harder to evaluate than one tied to a documented MCC, even when both carry the same manufacturer name.
Starter size and installed unit mix
Count starter buckets by labeled NEMA size and distinguish reversing, nonreversing and soft-starter units. Include overload relay identification and control voltage. A cabinet count alone hides whether the assembly contains usable controls, mismatched replacements or mostly empty positions.
VFD identity and configuration
For each drive bucket, provide the drive model, input voltage, horsepower and output current from its label. Identify bypass components, keypads and known faults. The bucket's physical size does not establish the installed drive capacity or which accessories are present.
Bus ratings and assembly completeness
Supply the MCC bus amperage, voltage and short-circuit rating shown on its documentation. Note missing bus connection pieces, barriers, doors or terminal blocks. Keeping section identification and matching hardware together gives a clearer picture of the assembly than photographs of separated cabinets alone.
Operating history and exposure
Report the last operating date, known trips or drive faults, and any water exposure, corrosion or overheating. Available maintenance records help explain the history. Describe condition bucket by bucket; one failed pump-control unit should not obscure the condition of the rest of the lineup.
For broader pricing context, read our guide: Used switchgear value on the secondary market.
What to Send for an Accurate Quote
- Overall photos showing the complete MCC front, section sequence, occupied positions and any loose buckets included in the offer.
- Readable lineup nameplates showing manufacturer, family, serial number, voltage, bus rating and short-circuit information, plus available UL 845 markings.
- A bucket spreadsheet with position number, quantity, catalog number, NEMA starter size, control voltage and the motor or circuit previously served.
- VFD and soft-starter labels showing exact model and electrical ratings, with bypass equipment, keypads and known faults noted separately.
- Current bucket schedules, one-line diagrams, unit schematics and maintenance records, identifying changes that no longer match the original drawings.
- Site city, shutdown window, removal deadline, section dimensions, loading route and any neighboring MCC sections or cooling circuits that must stay operational.
When Companies Sell motor control centers
- A chilled-water plant upgrade changes pump controls, leaving the former MCC and identifiable starter or VFD buckets available after the replacement plant is operating.
- A cooling-tower replacement retires fan-control circuits, releasing surplus motor-control units while other sections of the mechanical plant remain in service.
- A data center closure makes a complete mechanical-plant MCC lineup available, with bucket schedules and operating records retained before the room is cleared.
- An industrial facility standardizes its motor-control platform and offers unused spare buckets alongside documented sections removed during the conversion.
Removal, Safety, and Logistics
Removal is coordinated with your electrician or facility team around cooling continuity and site access. The MCC must be de-energized and locked out by qualified electricians before disconnection or removal work. Do not open energized compartments or withdraw live buckets to obtain quote photos. Identify sections that stay in service before planning separation. When we purchase, de-installation, rigging and insured freight are included, with no removal or recycling fees deducted from the offer. Pickup is typically scheduled within a few business days after acceptance. Keep section labels, bucket schedules, matching doors and connection hardware associated with the purchased equipment during handoff.
Power Equipment Removal Is Planned Before Pickup
This owner-provided project photo shows data center power equipment secured on a flatbed during a removal. Switchgear sections, breakers, and transfer equipment are heavy, so dimensions, weights, access routes, and rigging needs are confirmed with your team before the truck arrives.

Get a Written Offer for Your Motor Control Centers
Send nameplate photos, quantities, and your removal timeline. We reply with a written offer within 24 hours of receiving the list and photos.
Motor Control Centers: Seller Questions
Can I offer spare MCC starter buckets without the original lineup?
Yes. List each spare bucket separately and provide its manufacturer, equipment family, catalog number, NEMA starter size and control voltage. Include available records identifying the original MCC. Photographs should show the door, labels and any missing components without requiring electrical work. A loose bucket can have component value, but its fit cannot be established from the brand or exterior dimensions alone.
Does a NEMA starter size describe the physical size of an MCC bucket?
No. Record the NEMA starter size from the starter identification, and record bucket dimensions separately. For example, Eaton documents Freedom starter units in NEMA Sizes 1 through 5, but that label is not a substitute for the unit catalog number or mounting details. Include the motor horsepower, voltage and overload information where documented. Do not assign a starter size from the compartment height or door appearance.
What details distinguish a VFD bucket from a starter bucket in my MCC list?
Identify the installed drive by model, input voltage, horsepower and output current. For a conventional starter bucket, identify the contactor, labeled NEMA size and overload relay instead. Keep soft starters in a separate category. Note whether a VFD unit includes bypass equipment and whether its keypad is present. This inventory prevents several different motor-control configurations from being described simply as pump starters.
Can I sell retired cooling-plant MCC sections while adjacent sections remain active?
You can submit those sections for evaluation, but identify the exact sale boundary and remaining cooling loads in the asset list. Your facility team and qualified electricians must establish the shutdown and isolation requirements before disconnection. Do not assume a surplus bucket or section can be removed safely because its motor is no longer running. Share the available drawings and access window so removal planning protects the operating plant.
Will a failed drive bucket prevent an offer on the rest of my MCC?
A failed unit does not automatically rule out evaluating the lineup. Disclose the fault, missing parts and any related damage, and identify intact units separately. Older or non-working equipment can still have resale or parts value; what cannot be resold is recycled responsibly. The written offer depends on the documented equipment mix and condition. Payment is by company check or wire transfer, on pickup or per agreed terms for larger projects.
Related Switchgear We Buy
- Low-Voltage Switchgear
- New Surplus Switchgear
- Obsolete Switchgear & Breakers
- Damaged or Non-Working Switchgear
- All Electrical Switchgear
Motor Control Centers Brands We Buy
Get a written offer within 24 hours
Send your asset list and we respond with a firm written offer, typically within one business day. We pay top dollar, handle rigging and freight, and provide secure data wiping with a certificate on request.
Call 951-403-5738 or request a quote online.