We Buy Used Low-Voltage Power Circuit Breakers
Data Center Buyers buys used and surplus UL 1066 draw-out low-voltage power circuit breakers throughout the US and Canada. We consider single spares and breaker lots released by data center upgrades or shutdowns. Send an asset list with nameplate, trip-unit, and cassette photos for a written offer within 24 hours, typically one business day. Call 951-403-5738 or request a quote online.

Selling Low-Voltage Power Circuit Breakers: What to Know
A loose power breaker is not identified by amperage alone. This page covers draw-out low-voltage power circuit breakers associated with UL 1066 and ANSI C37.13, including families with frames in the 800–6000 A range. These breakers can come from data center main, tie, and feeder positions or from spare holdings supporting an existing power train. Manufacturer tables distinguish interrupting ratings at different voltages, so a breaker removed from a 480 V installation still needs its complete rating label. Record the original lineup and cell designation when available. That context helps establish what configuration the seller actually has, rather than treating every breaker of similar size as equivalent.
When a colocation facility replaces its electrical distribution platform, its spare draw-out breakers may no longer support the new lineup. A smaller facility or an industrial plant retaining that platform may still need compatible equipment. Frame size, installed trip unit, control accessories, and cassette identification all affect that possibility. Keep each breaker's records and associated hardware together, but do not remove a cassette from gear that must remain operational. Data Center Buyers purchases equipment from sellers; submit installed assets or stored spares with their current condition clearly described. Older or non-working breakers can still have resale or parts value, while equipment that cannot be resold is recycled responsibly.
Low-Voltage Power Circuit Breakers We Buy
Identifiable UL 1066 breaker families
- Eaton Magnum DS draw-out power circuit breakers, with the frame and Digitrip identification recorded where fitted.
- Siemens WL draw-out breakers marked UL 1066 / ANSI C37.13, rather than relying on the WL family name alone.
- ABB SACE Emax 2 UL 1066 draw-out power breakers, including larger-frame units with their Ekip trip-unit details.
- Schneider Electric MasterPacT MTZ UL/ANSI draw-out power breakers with UL 1066 identification and complete catalog information.
Main, tie, and feeder breaker ratings
- 800–1600 A frames offered individually or as identified spare lots, with actual sensor and trip ratings listed separately.
- 2000–3200 A frames removed from retained or replaced power trains, with the original cell position noted where known.
- 4000–6000 A frames where available in the identified manufacturer's UL 1066 range; not every family includes every rating.
- Three-pole and four-pole draw-out configurations, with interrupting and short-time withstand ratings copied from the applicable label or records.
Loose breakers and matched draw-out assemblies
- Removed breaker assemblies with intact trip units, primary disconnects, secondary connectors, and clearly identified installed accessories.
- Breaker-and-cassette sets where both components are surplus and their matching identification can be documented without affecting active equipment.
- Never-installed spare breakers with original packaging, factory documents, and storage history supplied by the seller.
- Mixed used breaker lots sorted by exact catalog number, with missing cassettes, incomplete assemblies, or known faults disclosed per unit.
What Affects Your Offer for low-voltage power circuit breakers
Exact frame and draw-out compatibility
Supply the complete breaker catalog number, frame designation, pole count, and cassette identification if available. Similar dimensions or matching ampere ratings do not establish interchangeability. Details about the original lineup and cell help evaluate a loose breaker whose receiving equipment is not included.
Trip unit and installed current rating
Photograph the trip-unit face and labels for the sensor and rating plug where fitted. Frame amperes, installed current rating, and adjustable protection settings are different information. Missing trip units or unidentified replacement electronics make the assembly harder to evaluate than a documented, complete breaker.
Voltage, interruption, and withstand ratings
Record the voltage associated with each interrupting rating rather than submitting a kA number by itself. Include the short-time withstand rating and duration when documented. These are distinct ratings; an offer depends on the specific configuration, not a family's largest published capability.
Cassette and control-accessory completeness
Identify whether the offer includes the breaker alone or its matching draw-out cassette. List installed shunt trips, undervoltage releases, charging motors, and their control voltages from available labels or records. Missing connectors, damaged disconnects, or undocumented accessory changes can limit potential reuse.
Condition and traceable service history
Provide the last operating date, available maintenance reports, recorded operation counts, and known faults. Disclose heat damage, moisture exposure, cracked insulation, or storage contamination without attempting electrical inspection yourself. A spare kept in protective packaging presents a different condition question from an undocumented field removal.
For broader pricing context, read our guide: Used switchgear value on the secondary market.
What to Send for an Accurate Quote
- An asset list with quantities, manufacturer, complete breaker catalog number, serial number, frame designation, and pole count; give mixed lots a separate identifier for each configuration.
- Readable breaker nameplate photos showing UL 1066 identification, voltage, frame amperes, interrupting ratings, and any available short-time withstand information; do not open energized compartments for photos.
- Trip-unit face and identification photos, plus sensor or rating-plug markings where safely accessible; include existing protection-setting records without changing settings to prepare a quote.
- Exterior photos of each already-removed breaker, its accessible disconnects and connectors, and any matching cassette; state clearly if the cassette will remain in the seller's lineup.
- Available maintenance reports, factory documents, original cell or lineup references, and accessory lists with control voltages; disclose missing parts, known failures, and storage conditions for spare breakers.
- Site city in the US or Canada, ownership confirmation, current installed or removed status, shutdown window, loading access, and removal deadline; identify neighboring equipment that must remain operational.
When Companies Sell low-voltage power circuit breakers
- A data center power-train refresh changes breaker platforms, leaving labeled UL 1066 spare breakers that no longer match the replacement lineup once the facility releases them from its spare holdings.
- A colocation operator retires one distribution path after a staged consolidation and offers its draw-out main, tie, and feeder breakers only after the operating team confirms they are surplus.
- An electrical contractor finishes a revised critical-power project with never-installed draw-out power breakers remaining; original order records identify the intended frame, trip unit, and matching cassette configuration.
- An industrial facility replaces a low-voltage lineup but retains other electrical rooms, offering only breakers that are no longer needed and keeping required operating spares out of the sale.
Removal, Safety, and Logistics
Coordinate breaker removal with the seller's electrician or facility team. Equipment must be de-energized and locked out by qualified electricians before disconnection, with isolation coordinated around any adjacent live sections. Do not rack out or dismantle equipment merely to obtain quote photos. When we purchase, de-installation, rigging, and insured freight are included, with no removal or recycling fees deducted from the offer. Keep each breaker associated with its identified cassette and records when both are included. Pickup is typically scheduled within a few business days after acceptance, around access, security, and uptime needs. Payment is by company check or wire transfer, on pickup or per agreed terms for larger projects.
Power Equipment Removal Is Planned Before Pickup
This owner-provided project photo shows data center power equipment secured on a flatbed during a removal. Switchgear sections, breakers, and transfer equipment are heavy, so dimensions, weights, access routes, and rigging needs are confirmed with your team before the truck arrives.

Get a Written Offer for Your Low-Voltage Power Circuit Breakers
Send nameplate photos, quantities, and your removal timeline. We reply with a written offer within 24 hours of receiving the list and photos.
Low-Voltage Power Circuit Breakers: Seller Questions
Does the WL or Emax 2 family name prove my draw-out breaker is UL 1066?
No. A family name or draw-out construction alone does not establish the applicable standard. Send the breaker label and complete catalog number so its actual version can be identified. This page focuses on UL 1066 low-voltage power circuit breakers. UL 489 insulated-case breakers are a separate category, even when their appearance or family name resembles a power breaker. If the label is unreadable, submit available factory records rather than guessing.
Can I offer a UL 1066 draw-out breaker while its cassette stays in service?
Yes, you can submit the loose breaker with the cassette excluded. State that exclusion clearly and provide the original cell or cassette identification from existing records where available. Do not disturb a cassette serving active equipment to complete a sale package. A matching surplus cassette can help document a complete draw-out assembly, but it is not required to submit an individual breaker for consideration.
Should I list a power breaker's frame amperes or its trip-unit setting?
List both, along with the installed sensor and rating plug where applicable. The frame rating describes the breaker frame, while the installed rating components and protection settings describe its current configuration. Photograph the labels and preserve available setting records. Do not adjust protection settings for a quote. Two breakers with the same frame amperes can have different installed trip units and current ratings, so a single ampere number leaves important information missing.
Are two 480 V draw-out power breakers interchangeable if their frames match?
Not necessarily. The complete catalog configuration, cassette arrangement, pole count, disconnects, control wiring, and protection equipment matter as well. Record the interrupting rating at the applicable voltage and any documented short-time withstand rating. We evaluate the equipment you offer; similarity to another breaker is not a statement that it will fit a particular cell. Keep original lineup references and accessory documentation with the breaker to reduce identification uncertainty.
Can a spare power breaker with no recent service report still be submitted?
Yes. Describe it as a stored spare and provide its labels, storage history, last known use, and any older records. Do not describe the breaker as operational solely because it looks clean or has not been installed. Identify missing trip units, damaged connectors, or known mechanical problems. Data Center Buyers can consider older or non-working equipment for resale or parts value, but the actual condition and completeness affect the offer.
Related Switchgear We Buy
- Low-Voltage Switchgear
- Insulated-Case Circuit Breakers
- Switchgear Parts & Components
- Obsolete Switchgear & Breakers
- All Electrical Switchgear
Low-Voltage Power Circuit Breakers Brands We Buy
Get a written offer within 24 hours
Send your asset list and we respond with a firm written offer, typically within one business day. We pay top dollar, handle rigging and freight, and provide secure data wiping with a certificate on request.
Call 951-403-5738 or request a quote online.